Are thermal calculations done in the same way for all building elements?
Generally speaking, yes - all calculations are done by the 'combined method'. However, ground floors differ slightly from other building elements in the information that is required. If requesting a calculation for a ground floor, please ensure that you provide a floor area and length of the exposed perimeter (i.e. the length of new floor along outside-facing walls). This allows us to calculate a perimeter/area ratio, which is crucial in the floor calculation.
Can a breather membrane be laid directly over insulation boards?
Different breather membrane manufacturers have different guidelines for their products, and these should always be consulted prior to installation. It may be possible to lay the breather membrane on the insulation, but with a counter batten airspace above.
If you would like to discuss application of any specific project, please contact our Technical Services.
Can I get a U-value calculated for my flat roofing project?
Absolutely! Please contact our freephone technical helpline on 01543 678777.
Can I recess cables into PIR insulation boards?
Cables should not be recessed into the insulation boards. They may be laid between two layers of boards with the cabling oversized to accommodate for an increase in operating temperature. If cables penetrate an insulation layer, PIR will have no detrimental effect on cable sheathing.
Further guidance on the above should be obtained from a qualified electrician.
Can tapered insulation be used on an existing flat roof?
Yes. Tapered insulation can be designed for both new and existing roofs.
For refurbishment projects, the existing roof construction should be assessed before a tapered insulation scheme is designed. The survey and design should consider the existing roof dimensions, drainage points, falls, obstructions, roof condition and the proposed new roof build-up.
Does thicker insulation always provide better thermal performance?
Increasing insulation thickness will generally increase the thermal resistance of the insulation layer, but thickness alone does not determine the thermal performance of a complete roof.
The thermal conductivity of the insulation, the other components within the roof build-up and the construction details all contribute to the final U-value.
Different insulation materials can therefore achieve similar thermal performance at different thicknesses.
This is particularly relevant where roof build-up height is restricted, because high-performance insulation can help achieve a required thermal target without simply increasing the thickness of conventional insulation.
How is a tapered insulation scheme designed?
A tapered insulation scheme is designed around the geometry and drainage requirements of the individual roof.
The design process should consider factors such as:
- Roof dimensions and geometry
- Drainage outlets and gutters
- Existing falls and backfalls
- Rooflights and other obstructions
- Required insulation performance
- The structural deck
- Waterproofing system
- Required roof build-up
-
Upstands and perimeter details
Gradient provides a design service that produces a pre-designed, dimensionally accurate tapered insulation solution with detailed layout drawings.
How thick do I need to insulate?
We recommend that you seek advice from your architect, designer, energy assessor etc. to determine the appropriate insulation thickness. If you already know the desired performance, you can contact our Technical Services team for U-value calculations or look up the required R-value and corresponding thickness in the technical datasheet.
The cleanest energy for heating and cooling, is the energy you do not have to use. That is why we recommend to insulate a flat roof to a higher standard than the minimum requirement. We recommend a minimum of 45 mm Deck-VQ® (Lambda (λ) = 0,009 W/mK) for renovation and 60 mm (Lambda (λ) = 0,008 W/mK) for new build.
Speak with our technical experts
What air gap is required between insulation and breather membrane?
This should be confirmed in the membrane manufacturer's BBA certificate, though 25mm to 50mm is typical.
What if I cannot provide all of the information required for thermal calculations of a specific project?
It is possible for us to make certain assumptions when performing a calculation, but this can reduce the accuracy of the final result. Assumptions are routinely made about the types of fixings to be used, but we will always try to inform you if a general figure has been used where more accurate data could affect the calculation result.