Can a flat roof survey tell me if my insulation is adequate?
Not necessarily. A visual survey may identify information about the apparent roof build-up, but it cannot reliably confirm the condition, moisture content or thickness of concealed insulation. Where this information is required, further investigation such as core sampling may be necessary. The applicable thermal requirements also depend on factors including the building, the work being undertaken and which Building Regulations provisions apply.
Can I get a U-value calculated for my flat roofing project?
Absolutely! Please contact our freephone technical helpline on 01543 678777.
Can tapered insulation be used on an existing flat roof?
Yes. Tapered insulation can be designed for both new and existing roofs.
For refurbishment projects, the existing roof construction should be assessed before a tapered insulation scheme is designed. The survey and design should consider the existing roof dimensions, drainage points, falls, obstructions, roof condition and the proposed new roof build-up.
Do I need an intrusive survey or core samples?
Not every roof survey requires intrusive investigation. If the purpose is to identify visible defects or drainage issues, a visual assessment may be sufficient. However, where the condition of the underlying roof build-up, moisture levels or insulation needs to be established, intrusive investigation may be recommended. The appropriate scope will depend on the condition of the roof and the reason for the survey.
Does thicker insulation always provide better thermal performance?
Increasing insulation thickness will generally increase the thermal resistance of the insulation layer, but thickness alone does not determine the thermal performance of a complete roof.
The thermal conductivity of the insulation, the other components within the roof build-up and the construction details all contribute to the final U-value.
Different insulation materials can therefore achieve similar thermal performance at different thicknesses.
This is particularly relevant where roof build-up height is restricted, because high-performance insulation can help achieve a required thermal target without simply increasing the thickness of conventional insulation.
How can I improve the thermal performance of an existing flat roof?
Improving an existing flat roof's thermal performance may involve adding insulation as part of a refurbishment or overlay system, subject to the condition and construction of the existing roof.
The appropriate solution depends on factors such as:
- Existing roof construction
- Existing waterproofing
- Available build-up height
- Required U-value
- Moisture and condensation considerations
- Drainage
- Existing roof condition
-
Upstands and junctions
Where available space is restricted, high-performance insulation such as vacuum insulation can provide an option for achieving improved thermal performance without requiring the same thickness as some conventional insulation products. Gradient's Deck-VQ® has been used in refurbishment projects where existing roof height and parapet constraints limited the available build-up.
How do I prevent thermal bridging through a flat roof?
Thermal bridging occurs where heat can flow more readily through part of a building element because of a change in material, geometry or construction.
In a flat roof, thermal bridging can occur around areas such as junctions, penetrations, parapets, rooflights and structural elements.
Good design should aim to maintain continuity of insulation wherever possible and address junctions and details appropriately.
The thermal performance of the complete roof build-up should be assessed rather than considering the insulation product in isolation. Accurate U-value calculations can help determine the thermal performance of the proposed construction. Gradient states that its U-value calculations are based on the relevant calculation methodology, including BS EN ISO 6946 for building elements.
How is a tapered insulation scheme designed?
A tapered insulation scheme is designed around the geometry and drainage requirements of the individual roof.
The design process should consider factors such as:
- Roof dimensions and geometry
- Drainage outlets and gutters
- Existing falls and backfalls
- Rooflights and other obstructions
- Required insulation performance
- The structural deck
- Waterproofing system
- Required roof build-up
-
Upstands and perimeter details
Gradient provides a design service that produces a pre-designed, dimensionally accurate tapered insulation solution with detailed layout drawings.
What if I cannot provide all of the information required for thermal calculations of a specific project?
It is possible for us to make certain assumptions when performing a calculation, but this can reduce the accuracy of the final result. Assumptions are routinely made about the types of fixings to be used, but we will always try to inform you if a general figure has been used where more accurate data could affect the calculation result.
What is a warm flat roof construction?
A warm flat roof is a roof construction where the insulation is positioned above the structural roof deck, keeping the deck and structure on the warm side of the insulation.
A typical warm roof build-up may include the structural deck, vapour control layer, insulation and waterproofing system. The exact arrangement depends on the roof construction and waterproofing system being used. Warm roof construction can provide continuous insulation across the roof, helping to reduce heat loss and improve the thermal performance of the building. The complete roof build-up should be designed to meet the required thermal, moisture, structural and fire performance criteria.